• 100A Contactor - choice of coil voltages

A range of single pole on/off contactors with a choice of coil voltages.

These contactors can carry:

- Interrupted loads of up to 100A and peak currents up to 185A short term duty.*

- Uninterrupted loads of up to 125A and peak currents up to 230A short term duty.*

Rated Fault Current Breaking Capacity (Icn) 5ms Time Constant:
- With blowouts         -   600A at 80V DC*
- Without blowouts   -   600A at 48V DC*

Maximum Recommended Contact Voltages:
- With blowouts         -   96V*
- Without blowouts   -   48V*

Power connections are via M8 terminal studs and coil connections are 6.4 mm push-on spades.

Mounting brackets are supplied, mounting can be horizontal or vertical, when vertical the M8 contact studs should point upwards.

Dimensions (approx):

Length 94 mm

Width 50.5 mm

Height 39 mm

Weight 0.5 kg approx.

*Manufacturers figures.

100A Contactor - choice of coil voltages

  • Product Code: CT-100
  • Availability: Pre-Order
  • £52.50

  • Ex Tax: £43.75

Available Options


Tags: 100A, Contactor, choice of coil voltages,