• 80A Contactor - choice of coil voltages

A range of single pole on/off contactors with a choice of coil voltages.

These contactors can carry:*

- Interrupted loads of up to 80A and peak currents up to 145A short term duty.

- Uninterrupted loads of up to 80A and peak currents up to 145A short term duty.

Rated Fault Current Breaking Capacity (Icn) 5ms Time Constant:
- With blowouts         -   400A at 96V DC
- Without blowouts   -   400A at 48V DC

Rated Fault Current Breaking Capacity (Icn) Resistive Load:
- With blowouts         -   120A at 96V DC
- Without blowouts   -   120A at 48V DC

Maximum Recommended Contact Voltages:
- With blowouts         -   96V
- Without blowouts   -   48V

Power connections are via M8 terminal studs and coil connections are 6.4 mm push-on spades.

Mounting holes are included, mounting can be horizontal or vertical, when vertical the M6 contact studs should point upwards.

Dimensions (approx):

Length 81.5 mm

Width 36 mm

Height 36 mm

Weight 0.3 kg approx.

*Manufacturers figures.

80A Contactor - choice of coil voltages

  • Product Code: CT-80
  • Availability: Pre-Order
  • £30.30

  • Ex Tax: £25.25

Available Options


Tags: 80A, Contactor, choice of coil voltages,